ASTM A179 Heat exchanger Seamless Steel Tubes

Pipe ordered under this specification is for tubular heat exchangers, condensers, and similar heat transfer apparatus.   Size: 13.1mm-660mm Wall Thickness:  2mm-100mm End:  plain end,beveled end. Length:  5.8m,6m,11.8m,12m or customerized. MOQ: 5 Tons Payment terms:LC/TT/DP

Products Details

Application of ASTM A179/SA179 Seamless Cold Drawn Low Carbon Steel Heat Exchanger And Condenser Tubes 

Pipe ordered under this specification is for tubular heat exchangers, condensers, and similar heat transfer apparatus

Details of ASTM A179/SA179 We can supply

Manufacture:Seamless process :cold drawn only Size: O.D.: 10.0~76mm  W.T.: 2~10mm      Length: 6M or specified length as required. Ends: Plain End, Beveled End.

Manufacturing Process of ASTM A179/SA179 Seamless Cold Drawn Low Carbon Steel Heat Exchanger And Condenser Tubes 

The tubes shall be made by the seamless process and shall be cold drawn .

Chemical Composition of ASTM A179/SA179

Grade and Chemical Composition (%)

Chemical Composition

C

Mn

P≤

S≤

Si≤

0.06-0.18

0.27-0.63

0.035

0.035

0.25 

Dimension tolerance of ASTM A179/SA179:

Tolerance of OD and W.T(SA-450/SA-450M):

OD In (mm)

+

-

WT In(mm)

+

-

<1(25.4)

0.10

0.10

≤1.1/2(38.1)

20%

0

1~1.1/2(25.4~38.1)

0.15

0.15

>1.1/2(38.1)

22%

0

>1.1/2~<2(38.1~50.8)

0.20

0.20

 

 

 

2~<2.1/2(50.8~63.5)

0.25

0.25

 

 

 

2.1/2~<3(63.5~76.2)

0.30

0.30

 

 

 

3~4(76.2~101.6)

0.38

0.38

 

 

 

>4~7.1/2(101.6~190.5)

0.38

0.64

 

 

 

>7.1/2~9(190.5~228.6)

0.38

1.14

     

Mechanical Tests Required

Flattening test Flaring test Flange test Hardness test Hydro-static test

Ordering information

Quantity ( feet, meters, or number of lengths) Name of material(seamless tubes) Manufacture(cold-drawn) Size (outside diameter and minimum wall thickness ) Length (specific and random) Optional requirements Test report required Specification number

Heat treatment

Tubes shall be heat treated after the final cold drawn pass at a temperature of 1200°F or higher.

Appearance for ASTM A179/SA179

A sufficient number of visual surface imperfections to provide seasonable assurance that they have been properly evaluated with respect to depth. The defect shall be removed or cut off within the limits of requirements on length. The finished pipe shall be reasonably straight.

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours